SUPER MICRO Computer SUPERSERVER 6012P-6 User Manual Page 22

  • Download
  • Add to my manuals
  • Print
  • Page
    / 110
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 21
2-4
SUPERSERVER 6012P-6 Manual
Installing the Chassis Rails:
Position the fixed chassis rail sections you just removed along the side of
the 6012P-6 making sure the screw holes line up. Note that these two rails
are left/right specific. Screw the rail securely to the side of the chassis
(see Figure 2-2). Repeat this procedure for the other rail on the other side
of the chassis. You will also need to attach the rail brackets when installng
into a telco rack.
Locking Tabs: As you have seen, both chassis rails have a locking tab,
which serves two functions. The first is to lock the server into place
when installed and pushed fully into the rack, which is its normal position.
Secondly, these tabs also lock the server in place when fully extended
from the rack. This prevents the server from coming completely out of
the rack when you pull it out for servicing.
Figure 2-2. Installing Chassis Rails
Installing the Rack Rails:
Determine where you want to place the SuperServer 6012P-6 in the rack.
(See Rack and Server Precautions in Section 2-3.) Position the fixed rack
rail/sliding rail guide assemblies at the desired location in the rack, keeping
the sliding rail guide facing the inside of the rack. Screw the assembly
securely to the rack using the brackets provided. Attach the other assem-
Page view 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 109 110

Comments to this Manuals

No comments