SUPERSERVER 6016T-6RFT+SUPERSERVER 6016T-6RF+ SUPER®USER’S MANUAL1.0a

Page 2 - Release Date: August 26, 2013

1-2SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual1-2 Serverboard FeaturesAt the heart of the SuperServer 6016T-6RFT+/6016T-6RF+ lies the X8DTU-

Page 3 - Manual Organization

7-12SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualSATA#1 Confi gurationIf Compatible is selected, it sets SATA#1 to legacy compatibility mode, w

Page 4

Chapter 7: BIOS7-13LBA/Large ModeLBA (Logical Block Addressing) is a method of addressing data on a disk drive. In the LBA mode, the maximum drive cap

Page 5

7-14SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualSelect SWDMA2 to allow the BIOS to use Single Word DMA mode 2. It has a data transfer rate of

Page 6 - Table of Contents

Chapter 7: BIOS7-15Plug & Play OSSelecting Yes allows the OS to confi gure Plug & Play devices. (This is not required for system boot if Plug &

Page 7 - Chapter 3 System Interface

7-16SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualSuper IO Device Confi guration Serial Port1 Address/ Serial Port2 AddressThis option specifi e

Page 8

Chapter 7: BIOS7-17to keep Console Redirection active during POST and Boot Loader. The options are Disabled, Boot Loader, and Always.Terminal TypeThis

Page 9 - Introduction

7-18SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualCPU 1 Temperature/CPU 2 Temperature/System TemperatureThis feature displays current temperatu

Page 10 - 1-2 Serverboard Features

Chapter 7: BIOS7-192. The information provided above is for your reference only. For more information on thermal management, please refer to Intel’s W

Page 11 - 1-3 Server Chassis Features

7-20SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualACPI APIC Support (Available ACPI Aware O/S='Yes')Select Enabled to include the ACP

Page 12 - Cooling System

Chapter 7: BIOS7-21BIOS AC[SCLEAN] (Available when Intel TXT(LT) Initialization is enabled)Select Enabled to allow the processor to load an authentica

Page 13 - System Block Diagram

1-3Chapter 1: Introduction10 supported (RAID 5 is supported with Windows OS only). The SATA drives are hot-swappable units. Note: You must have RAID s

Page 14 - 1-4 Contacting Supermicro

7-22SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualExecute TPM Command (Available when TCG/TPM Support = 'Yes')Select Enabled to execu

Page 15 - Server Installation

Chapter 7: BIOS7-23• SEL Record Type• Event Timestamp• Generator ID• Event Message Format Ver.• Event Sensor Type• Event Sensor Number,• Event Dir Typ

Page 16 - 2-4 Warnings and Precautions

7-24SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manualassigned to the client can be reassigned to a new client. Select Static (Static Allocation) t

Page 17 - Rack Mounting Considerations

Chapter 7: BIOS7-25after an operating system failure is detected. The options are [5 Min], [1 Min], [30 Sec], and [10 Sec].DMI Event Log Confi guratio

Page 18 - Installing the Inner Rails

7-26SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualSupervisor Password This item indicates if a Supervisor password has been entered for the sys

Page 19 - Installing the Outer Rails

Chapter 7: BIOS7-277-5 Boot Confi gurationUse this feature to confi gure boot settings. Boot Device PriorityThis feature allows the user to specify the

Page 20

7-28SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual7-6 Exit OptionsSelect the Exit tab from the AMI BIOS Setup Utility screen to enter the Exit

Page 21

Chapter 7: BIOS7-29Load Fail-Safe DefaultsTo set this feature, select Load Fail-Safe Defaults from the Exit menu and press <Enter>. The Fail-Saf

Page 22

7-30SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualNotes

Page 23

A-1Appendix A: BIOS Error Beep CodesAppendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the

Page 24

1-4SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualPCI Expansion SlotsTwo riser cards are included. The RSC-R1UU-E8R+ is located on the right sid

Page 25 - System Interface

A-2SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualNotes

Page 26 - 3-3 Control Panel LEDs

B-1Appendix B: System Specifi cationsAppendix B System Specifi cationsProcessorsSingle or dual Intel® 5500/5600 Series processors in LGA1366 socketsNote

Page 27 - 3-4 Drive Carrier LEDs

B-2SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualExpansion Slots Left side: two PCI-E x8 add-on cards (w/ RSC-R1UU-2E8 riser)Right side: one PC

Page 28

B-3Appendix B: System Specifi cationsRegulatory ComplianceElectromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-3, CISPR 22 Class A

Page 29 - Chapter 4

B-4SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualNotes(continued from front)The products sold by Supermicro are not intended for and will not b

Page 30

1-5Chapter 1: IntroductionFigure 1-1. Intel 5520 + IOH-36D/ICH10R Chipset: System Block DiagramNote: This is a general block diagram. Please see Chap

Page 31 - ﺔﻴﺋﺎﺑﺮﻬﻜﻟﺍ

1-6SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose

Page 32 - Installation Instructions

Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your 6016T-6RFT+/6016T-

Page 33 - Circuit Breaker

2-2SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manualinstallation only in a Restricted Access Location (dedicated equipment rooms, service closets

Page 34 - Power Disconnection Warning

Chapter 2: Server Installation2-3Rack Mounting ConsiderationsAmbient Operating TemperatureIf installed in a closed or multi-unit rack assembly, the am

Page 35 - ילמשח קותינ ינפמ הרהזא

2-4SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual2-5 Installing the System into a RackThis section provides information on installing the 6016

Page 36 - Equipment Installation

Chapter 2: Server Installation2-5Installing the Outer RailsInstalling the Outer Rails to the Rack1. Measure the distance from the front rail to the r

Page 37 - Restricted Area

The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccur

Page 38 - Battery Handling

2-6SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualInstalling the Server into the RackInstalling the Chassis into a Rack (Figure 2-3)1. Confi rm t

Page 39

Chapter 2: Server Installation2-7Figure 2-3. Installing the Server into a Rack

Page 40 - Redundant Power Supplies

2-8SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual2-6 Checking the Serverboard SetupAfter you install the system in the rack, you will need to

Page 41 - Backplane Voltage

Chapter 2: Server Installation2-9Figure 2-4. Accessing the Inside of the System

Page 42

2-10SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual2-7 Checking the Drive Bay SetupNext, you should check to make sure the peripheral drives an

Page 43 - Product Disposal

Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel as well as others on the hard drive ca

Page 44 - רצומה קוליס

3-2SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualHDDIndicates IDE channel activity. On the 6016T-6RFT+/6016T-6RF+ this light indicates HDD and/

Page 45

Chapter 3: System Interface3-3PowerIndicates power is being supplied to the system's power supply units. This LED should normally be illuminated

Page 46 - Power Cable and AC Adapter

3-4SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualNotes

Page 47 - (UL/CSA ﻞﻤﺤﺗ ﻲﺘﻟﺍﺔﻣﻼﻋ )

4-1Chapter 4: Warning Statements for AC SystemsChapter 4Standardized Warning Statements for AC Systems4-1 About Standardized Warning StatementsThe fo

Page 48

iiiPrefacePrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the insta

Page 49 - Advanced Serverboard Setup

4-2SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualWarnung WICHTIGE SICHERHEITSHINWEISEDieses Warnsymbol bedeutet Gefahr. Sie befi nden sich in ei

Page 50 - Installing LGA1366 Processors

4-3Warning Statements for AC Systems안전을 위한 주의사항경고!이 경고 기호는 위험이 있음을 알려 줍니다. 작업자의 신체에 부상을 야기 할 수 있는 상태에 있게 됩니다. 모든 장비에 대한 작업을 수행하기 전에 전기회로와 관련된 위험요소들을 확

Page 51 - Load Plate

4-4SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualInstallation Instructions Warning!Read the installation instructions before connecting the sys

Page 52 - Installing the Heatsink

4-5Chapter 4: Warning Statements for AC SystemsCircuit Breaker Warning!This product relies on the building's installation for short-circuit (over

Page 53 - Removing the Heatsink

4-6SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualPower Disconnection Warning 電源切断の警告システムコンポーネントの取り付けまたは取り外しのために、シャーシー内部にアクセスするには、システムの電源はすべてのソー

Page 54 - • SAS cables (SAS0 ~ SAS3)

4-7Chapter 4: Warning Statements for AC Systems¡Advertencia! El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico qu

Page 55 - 5-4 I/O Ports

4-8SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualEquipment Installation機器の設置トレーニングを受け認定された人だけがこの装置の設置、交換、またはサービスを許可されています。 Warning!Only trained

Page 56 - 5-5 Installing Memory

4-9Chapter 4: Warning Statements for AC Systemsアクセス制限区域このユ ニットは、アクセス制限区域に設置されることを想定しています。アクセス制限区域は、特別なツール、鍵と錠前、その他のセキュリティの手段を用いてのみ出入りが可能です。 Warning!Th

Page 57

4-10SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualBattery Handling Warning!There is the danger of explosion if the battery is replaced incorrec

Page 58 - • 1.5V DIMMs

4-11Chapter 4: Warning Statements for AC SystemsWarnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur

Page 59 - • 1.35V DIMMs

SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualivChapter 5: Advanced Serverboard SetupChapter 5 provides detailed information on the X8DTU-6TF+

Page 60 - 5-6 Adding PCI Cards

4-12SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualWarnung Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, dass der Einhe

Page 61 - 5-7 Serverboard Details

4-13Chapter 4: Warning Statements for AC SystemsBackplane Voltageバックプレーンの電圧システムの稼働中は危険な電圧または電力が、バックプレーン上にかかっています。修理する際には注意ください。警告当系统正在进行时,背板上有很危险的电压或能

Page 62

4-14SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualComply with Local and National Electrical Codes Warning!Installation of the equipment must co

Page 63 - 5-8 Connector Defi nitions

4-15Chapter 4: Warning Statements for AC SystemsProduct Disposal Warning!Ultimate disposal of this product should be handled according to all national

Page 64

4-16SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualWaarschuwing De uiteindelijke verwijdering van dit product dient te geschieden in overeenstem

Page 65

4-17Chapter 4: Warning Statements for AC SystemsWarnungDie Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halt

Page 66 - Pin # Defi nition

4-18SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual Warning!When installing the product, use the provided or designated connection cables, power

Page 67

4-19Chapter 4: Warning Statements for AC SystemsAttention Lors de l'installation du produit, utilisez les bables de connection fournis ou désigné

Page 68

4-20SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualNotes

Page 69

Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install processors and heatsinks

Page 70

vPrefaceNotes

Page 71 - 5-9 Jumper Settings

5-2SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual5-2 Processor and Heatsink InstallationIMPORTANT! Always connect the power cord last and remo

Page 72

Chapter 5: Advanced Serverboard Setup5-31. After removing the plastic cap, use your thumb and the index fi nger to hold the CPU at the north and south

Page 73 - IPMI LAN Indicator

5-4SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualThermal GreaseCPU1. Place the heatsink on top of the CPU so that the four mounting holes are

Page 74

Chapter 5: Advanced Serverboard Setup5-51. Unplug the power cord from the power supply.1. Unscrew and remove the heatsink screws in the sequence sho

Page 75 - 5-11 SATA Port Connections

5-6SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual5-3 Connecting CablesNow that the processors are installed, the next step is to connect the ca

Page 76 - 5-12 Installing Software

Chapter 5: Advanced Serverboard Setup5-7Figure 5-1. Front Control Panel Header Pins (JF1)NMIx (key)3.3VUID Switch/VccNIC1 Active LEDNIC2 Active LEDRed

Page 77 - SuperDoctor III

5-8SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual5-5 Installing MemoryNote: Check the Supermicro web site for recommended memory modules.CAUTIO

Page 78 - 5-13 Onboard Battery

Chapter 5: Advanced Serverboard Setup5-9Memory Support for 5500 Processor(s)RDIMM Population w/5500 Processors InstalledDIMM Slots per ChannelDIMMs Po

Page 79 - Advanced Chassis Setup

5-10SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualNotes: Due to OS limitations, some operating systems may not show more than 4 GB of memory. D

Page 80 - 6-2 Control Panel

Chapter 5: Advanced Serverboard Setup5-11Possible System Memory Allocation & AvailabilitySystem Device Size Physical Memory Remaining (4 GB Total

Page 81 - 6-3 System Fans

viSUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualTable of ContentsChapter 1 Introduction1-1 Overview ...

Page 82 - Accessing the Drive Bays

5-12SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualPCI Slot/Card Confi gurationsRiser Card Expansion Card SupportedRSC-R1UU-2E8 (left side) 1x UI

Page 83 - Hard Drive Installation

Chapter 5: Advanced Serverboard Setup5-13Figure 5-4. SUPER X8DTU-6TF+/ Layout5-7 Serverboard DetailsNotes:TLAN1 and TLAN 2 are included on the X8DTU-

Page 84 - Hard Drive Backplane

5-14SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualX8DTU-6TF+/X8DTU-6F+ Quick ReferenceJumper Description Default SettingJBT1Clear CMOS See Sect

Page 85 - DVD-ROM Drive Installation

Chapter 5: Advanced Serverboard Setup5-155-8 Connector Defi nitionsATX Power Connector The primary ATX power supply con-nector meets the SSI EPS 12V sp

Page 86 - 6-4 Power Supply

5-16SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualNIC1 LEDThe NIC1 (Network Interface Control-ler) LED connection is located on pins 11 and 12

Page 87

Chapter 5: Advanced Serverboard Setup5-17Overheat (OH)/Fan Fail/PWR Fail/UID LEDConnect an LED to pins 7 and 8 of JF1 to provide advanced warning of c

Page 88

5-18SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualFan HeadersThe board has eight fan headers designated Fan1 through Fan8. FAN1 through FAN6 ar

Page 89 - Chapter 7

Chapter 5: Advanced Serverboard Setup5-19Chassis Intrusion A Chassis Intrusion header is located at JL1. Attach the appropriate cable to inform you of

Page 90 - 7-2 Main Setup

5-20SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualLAN (Ethernet) PortsTwo Ethernet ports (designated LAN1 and LAN2) are located beside the VGA

Page 91

Chapter 5: Advanced Serverboard Setup5-21Universal I/O Power ConnectorPin Defi nitions Pin# Defi nition Pin # Defi nitionB1 P5V A1 P3V3B2 P5

Page 92 - Boot Features

viiTable of ContentsInstalling the Server into a Telco Rack ... 2-62-6 Checking the Serverboa

Page 93 - Processor and Clock Options

5-22SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualTrusted Platform Module HeaderA Trusted Platform Module header (JTPM) is located next to the

Page 94

Chapter 5: Advanced Serverboard Setup5-235-9 Jumper SettingsExplanation of JumpersTo modify the operation of the serverboard, jumpers can be used to c

Page 95

5-24SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualLAN/TLAN Enable/Disable Change the setting of jumper JPL1 to enable or disable the LAN1 and L

Page 96 - QPI and IMC Confi guration

Chapter 5: Advanced Serverboard Setup5-255-10 Onboard IndicatorsLAN LEDsThe Ethernet ports (located beside the VGA port) have two LEDs. On each Gigabi

Page 97

5-26SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualBMC Heartbeat LEDState Defi nition Blink-ingBMC: NormalSAS Activity & SAS Heart

Page 98

Chapter 5: Advanced Serverboard Setup5-275-11 SATA Port ConnectionsSATA PortsThere are six Serial ATA Ports (I-SATA0~I-SATA 5) on the serverboard, wh

Page 99 - IDE/SATA Confi guration

5-28SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualFigure 5-5. Driver/Tool Installation Display Screen5-12 Installing SoftwareThe Supermicro ft

Page 100

Chapter 5: Advanced Serverboard Setup5-29SuperDoctor IIIThe SuperDoctor® III program is a web-based management tool that supports remote management ca

Page 101

5-30SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualFigure 5-7. SuperDoctor III Interface Display Screen (Remote Control)Note: The SuperDoctor

Page 102 - PCI/PnP Confi guration

Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform mainte-na

Page 103

viiiSUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualX8DTU-6TF+/X8DTU-6F+ Quick Reference ... 5-145-

Page 104 - Remote Access Confi guration

6-2SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualFigure 6-1. Chassis: Front and Rear Views6-2 Control PanelThe control panel (located on the f

Page 105 - Hardware Health Monitor

Chapter 6: Advanced Chassis Setup6-36-3 System FansFive 4-cm heavy duty counter-rotating fans provide the cooling for the 6016T-6RFT+/6016T-6RF+. Each

Page 106

6-4SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualFigure 6-2. System Cooling FansAccessing the Drive BaysHard Drives: Because of their hotswap

Page 107 - ACPI Confi guration

Chapter 6: Advanced Chassis Setup6-5Hard Drive InstallationThe hard drives are mounted in drive carriers to simplify their installation and removal fr

Page 108 - Intel TXT(LT) Confi guration

6-6SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualInstalling/Removing a Hard Drive1. To remove a carrier, push the release button located besid

Page 109 - Trusted Computing (Optional)

Chapter 6: Advanced Chassis Setup6-7DVD-ROM Drive InstallationThe top cover of the chassis must be opened to gain full access to the DVD-ROM drive bay

Page 110 - • SEL Record ID

6-8SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual6-4 Power SupplyThe SuperServer 6016T-6RFT+/6016T-6RF+ has a 700 watt redundant power supply c

Page 111 - Set LAN Confi guration

Chapter 6: Advanced Chassis Setup6-9Figure 6-5. Removing/Replacing the Power Supply12

Page 112

6-10SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualNotes

Page 113 - 7-4 Security Settings

Chapter 7: BIOS7-1Chapter 7 BIOS7-1 IntroductionThis chapter describes the AMI BIOS Setup Utility for the X8DTU-6F+/X8DTU-6TF+. The AMI ROM BIOS is st

Page 114

Chapter 1 Introduction1-1 OverviewThe SuperServer 6016T-6RFT+/6016T-6RF+ is a comprised of two main subsys-tems: the SC819TQ-R700U 1U server chassis a

Page 115 - 7-5 Boot Confi guration

7-2SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualNote: For AMI BIOS Recovery, please refer to the AMI BIOS Recovery Instructions posted on our

Page 116 - 7-6 Exit Options

Chapter 7: BIOS7-3System Overview: The following BIOS information will display.System Time/System Date Use this option to change the system time and d

Page 117 - Load Fail-Safe Defaults

7-4SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual7-3 Advanced Setup Confi gurationsUse the arrow keys to select Advanced and press <Enter>

Page 118

Chapter 7: BIOS7-5Hit 'Del' Message DisplaySelect Enabled to display "Press DEL to run Setup" during POST. The options are Enabled

Page 119 - BIOS Error Beep Codes

7-6SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual• Cache L2: This item displays the size of Cache L2 of the CPU for the moth-erboard.• Cache L3

Page 120

Chapter 7: BIOS7-7Intel® Virtualization Technology (Available when supported by the CPU)Select Enabled to use the feature of Virtualization Technology

Page 121 - System Specifi cations

7-8SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualC1E SupportSelect Enabled to use the feature of Enhanced Halt State. C1E signifi cantly reduces

Page 122

Chapter 7: BIOS7-9• Memory Reference Code: This item displays the memory reference code for the motherboard.• QPI Reference Code: This item displays t

Page 123 - Regulatory Compliance

7-10SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's ManualChannel InterleaveThis feature allows the user to confi gure the Memory Interleave settings fo

Page 124

Chapter 7: BIOS7-11IOH PCI-E Max Payload SizeSome add-on cards perform faster with the coalesce feature, which limits the payload size to 128B; while